Address: 100214, Ulugbek township, Tashkent, Uzbekistan
Tеl: +99871 2893463
Tel/Fax: +99871 2893560, +99871 2892263

"RADIOPREPARAT"
STATE ENTERPRISE

Manufacturing of radioisotope products
and Immune-enzymatic test systems

Kits for labelling

TECHNEPHORE, 99mTc

TECHNEPHORE, 99mTc is a diagnostic radiopharmaceutical and represents the complex of technetium-99m with oxabiphore (oxa-bis (ethylennitrilo) tetrametylenephosphonic acid). 

Indications

Technephore, 99mTc is suitable agent for bone scintigraphy, has proven valuable in the detection of primary and metastatic tumours, osteomyelitics, bone-joint tuberculosis etc.

Preparation of the radiopharmaceutical

  • Take one vial from the kit and place it in the lead shielding.
  • Aseptically introduce into the vial 5 ml of a sterile and pyrogen-free solution of Tc-99m pertechnetate.
  • When necessary the eluate from a generator may be diluted previously by saline solution to the

required radioactive concentration.

  • Shake carefully to dissolve the dried mixture.
  • The preparation is ready for use after dissolving completely of the dried reagent.
  • One vial is sufficient for 3 tests in adults.

Composition

 

Active substance.
In the one vial with lyophilized mixture:
In 1 ml of the radiopharmaceutical:
Technetium-99m
185 – 740 MBq
Sn(II)
0,10 mg
0,02 mg
Phosphorus
1,25 mg
0,25 mg

 Expiry: 1 year after production date - for kit.

               5 hours after preparation - for radiopharmaceutical «Technephore, 99mTc».

TECHNEPHYTE, 99mTc

TECHNEPHYTE, 99mTc is a diagnostic radiopharmaceutical and represents the colloidal solution of technetium-99m with phytine. The radiopharmaceutical is prepared in clinics directly before use.

Indications

Technephyte, 99mTc is suitable agent for liver scintigraphy, has proven valuable in the detection of the shape, size and presence of the damage of the liver and spleen at tumours, cirrhosis, hepatitis and others diseases.

Preparation of the radiopharmaceutical:

  • Take one vial from the kit and place it in the lead shielding.
  • When necessary the eluate from a generator may be diluted previously by saline solution to the required radioactive concentration.
  • Aseptically introduce into the vial 5 ml of a sterile and pyrogen-free solution of Tc-99m pertechnetate.
  • Shake carefully to dissolve the dried mixture.
  • The preparation is ready for use after dissolving completely of the dried reagent.
  • One vial is sufficient for 5 tests in adults.

Composition

Active substance.
In the one vial with lyophilized mixture:
In 1 ml of the radiopharmaceutical:
Technetium-99m
185 – 1480 MBq
Sn(II)
0,145 mg
0,029 mg
Phytine
11,0 mg
2,2 mg
Phosphorus
≤ 3,2 mg
≤ 0,64 mg

Expiry:     1 year after production date - for kit.

                 5 hours after preparation - for radiopharmaceutical «Technephyte, 99mTc».

  

TECHNEMEK, 99mTc

TECHNEMEK, 99mTc is a diagnostic radiopharmaceutical and represents the complex of technetium-99m with dimercaptosuccinic acid.

Indications

Technemek, 99mTc is suitable agent for scintigraphy of the kidneys, has proven valuable in the detection of the size, shape, position and presence of the damage of the kidneys and its function.

Preparation of the radiopharmaceutical:

  • Take one vial from the kit and place it in the lead shielding.
  • Aseptically introduce into the vial 5 ml of a sterile and pyrogen-free solution of Tc-99m pertechnetate.
  • Do not use a breather needle.
  • When necessary the eluate from a generator may be diluted previously by saline solution to the required radioactive concentration.
  • Shake carefully to dissolve the dried mixture.
  • The preparation is ready for use in 30 min after addition of the eluate.
  • One vial is sufficient for 10 tests in adults. 

  

MEZIDA, 99mTc

MEZIDA, 99mTc is a diagnostic radiopharmaceutical and represents the complex of technetium-99m with 2,4,6-trimethyl-phenylcarbamoylmethyliminodiacetic acid. The radiopharmaceutical is prepared in clinics directly before use.

Indications

Mezida, 99mTc is suitable agent for dynamic scintigraphy of the hepatobiliary system.

Preparation of the radiopharmaceutical:

  • Take one vial from the kit and place it in the lead shielding.
  • Aseptically introduce into the vial 1-8 ml of a sterile and pyrogen-free solution

of Tc-99m pertechnetate.

  • When necessary the eluate from a generator may be diluted previously by saline solution

to the required radioactive concentration.

  • Shake carefully to dissolve the dried mixture.
  • The preparation is ready for use in 30 min after addition of the eluate.
  • One vial is sufficient for 1-4 tests in adults. 

PENTATECH, 99mTc

PENTATECH, 99mTc is a diagnostic radiopharmaceutical and represents the complex of technetium-99m with Ca-Na3-diethylenetriaminepentaacetate (DTPA).

Indications

Pentatech, 99mTc is suitable agent for dinamic scintigraphy of the kidneys, for glomerular filtration rate measurements , for radionuclide angiocardiography, for visualization of the brain tumours.

Preparation of the radiopharmaceutical:

  • Take one vial from the kit and place it in the lead shielding.
  • Aseptically introduce into the vial 5 ml of a sterile and pyrogen-free solution of Tc-99m pertechnetate.
  • When necessary the eluate from a generator may be diluted previously by saline solution to the required radioactive concentration.
  • Shake carefully to dissolve the dried mixture.
  • The preparation is ready for use in 30 min after addition of the eluate.
  • One vial is sufficient for 5 tests in adults.

 

PYRPHOTECH, 99mTc

PYRPHOTECH, 99mTc is a diagnostic radiopharmaceutical and represents the complex of technetium-99m with pyrophosphate.

Indications

Pyrphotech, 99mTc is suitable agent for bone scintigraphy, detection of acute myocardial infarctions and malignant tumours of the ovaries, for the red blood cells (RBC) labeling in vivo.

 

TECHNETRIL, 99mTc

TECHNETRIL, 99mTc is a diagnostic radiopharmaceutical and represents the complex of technetium-99m with 2-methoxyisobutyl-isonitrile.

Indications

Technetril, 99mTc is suitable agent for evoluation of the myocardium perfusion at its different pathological states and for the scintigraphy of the malignant tumors of the lung and breast.

 

TECHNEMAG, 99mTc

TECHNEMAG, 99mTc is a diagnostic radiopharmaceutical and represents the complex of technetium-99m with mercaptoacetyltriglycine (MAG3). The radiopharmaceutical is prepared in clinics directly before use.

Indications

Technemag, 99mTc is suitable agent for evoluation of renal function radionuclide measurements.

Preparation of the radiopharmaceutical:

  • Take one vial from the kit and place it in the lead shielding.
  • Aseptically introduce into the vial 4 ml of a sterile and pyrogen-free solution of Tc-99m pertechnetate.
  • Do not use a breather needle.
  • When necessary the eluate from a generator may be diluted previously by saline solution to the required radioactive concentration.
  • Place the vial with the lead shield upright in a boiling water bath for 15 minutes. Timing for 15 minutes is begun as soon as the water being to boil again.
  • Remove the shielded vial from the water
  • The preparation is ready for use in 15 min after cooling of the vial to the room temperature.
  • One vial is sufficient for 2-5 tests in adults.

Composition

Active substance.
In the one vial with lyophilized mixture:
In 1 ml of the radiopharmaceutical:
Technetium-99m
37 – 185 MBq
SnCl2 x 2 H2O
0,024mg
0,006 mg
S-benzoyl-mercaptoacetyltriglycine
0,5 mg
0,125 mg
Sodium tartrate
20,0 mg
5,0 mg